Pacemaker or defibrillator generator replacement
Generator replacement in Tunis, Tunisia · Centre Urbain Nord
Planned replacement of a pacemaker or defibrillator generator whose battery is nearing its end, usually keeping the existing leads.
What is it?

When is it indicated?
The device check shows that the battery is reaching its limit; replacement is then scheduled before it runs out.
Rarely, a generator develops a fault or is subject to a manufacturer advisory; it is then replaced as a precaution.
If the heart has changed, the replacement can be used to upgrade, for example, to a defibrillator or a resynchronisation device, adding a lead if necessary.
If a lead is no longer working properly, it can be replaced or supplemented by a new one during the same procedure.
Preparation
Procedure
Positioning in a dedicated room, preventive antibiotic and local anaesthesia
Reopening of the old scar and removal of the generator from its pocket
Disconnection and electrical testing of the leads, with back-up pacing if necessary
Connection of the leads to the new generator, or addition of a lead if needed
Placement of the generator in the pocket and careful closure
Programming and check of the new device, reactivation of defibrillator therapies
Duration
30 minutes to 1 hour
Results
Patients often go home the same day or the next day. The wound must be kept clean and dry; local care and stitch removal, if needed, are explained. Everyday activities resume within a few days, avoiding strain on the arm on the operated side during the first week. Regular device checks continue as before.
Risks and side effects
These risks remain rare. Your physician will inform you in detail before the examination.